DC/DC Converter
TEN 40E Series, 40 Watt
•
Developed to maximize quality in a cost
efficient design
•
•
•
Excellent temperature capabilities
•
Minimal heat development due to high
efficiencies up to 93%
2” x 1” metal package (6-side shielded)
Wide 2:1 input voltage range:
9-18, 18-36, 36-75 VDC
•
Operating temperature range -40 to
+85°C
•
•
•
1600 VDC I/O-isolation
•
3-year product warranty
Remote On/Off and Trim function
Protection against short circuit,
overvoltage and overtemperature
UL 62368-1 IEC 62368-1
The TEN 40E is rounding out Traco Power’s existing 40 Watt product range.
Driven by current market trends this series was developed to maximize quality
and cost efficiency in one product. Due to a new design approach the TEN 40E
thus offers a cost efficient solution with not only no concession on quality or reliability but even improved specifications compared to its predecessor. It comes
in a standard 2” x 1” metal package with a 2:1 input voltage range. High efficiencies of up to 93% allow for an operating temperature range (natural convection) of -40 to +70°C without power derating (model dependent). Certified
according to the latest IT standard (IEC/EN/UL 62368-1) and equipped with
additional features like remote on/off function and protection against short circuit, overvoltage and over temperature the TEN 40E series is suitable for many
industrial applications.
Models
Order Code
Input Voltage
Range
TEN 40-1210E
TEN 40-1211E
TEN 40-1212E
TEN 40-1213E
TEN 40-1215E
TEN 40-1222E
TEN 40-1223E
TEN 40-1225E
TEN 40-2410E
TEN 40-2411E
TEN 40-2412E
TEN 40-2413E
TEN 40-2415E
TEN 40-2422E
TEN 40-2423E
TEN 40-2425E
TEN 40-4810E
TEN 40-4811E
TEN 40-4812E
TEN 40-4813E
TEN 40-4815E
TEN 40-4822E
TEN 40-4823E
TEN 40-4825E
www.tracopower.com
9 - 18 VDC
(12 VDC nom.)
18 - 36 VDC
(24 VDC nom.)
36 - 75 VDC
(48 VDC nom.)
Output 1
Output 2
Vnom
Imax
3.3 VDC
5 VDC
12 VDC
15 VDC
24 VDC
+12 VDC
+15 VDC
+24 VDC
3.3 VDC
5 VDC
12 VDC
15 VDC
24 VDC
+12 VDC
+15 VDC
+24 VDC
3.3 VDC
5 VDC
12 VDC
15 VDC
24 VDC
+12 VDC
+15 VDC
+24 VDC
12'200 mA
8'000 mA
3'333 mA
2'666 mA
1'666 mA
1'666 mA
1'333 mA
833 mA
12'200 mA
8'000 mA
3'333 mA
2'666 mA
1'666 mA
1'666 mA
1'333 mA
833 mA
12'200 mA
8'000 mA
3'333 mA
2'666 mA
1'666 mA
1'666 mA
1'333 mA
833 mA
November 30, 2022
Vnom
Efficiency
Imax
–12 VDC
–15 VDC
–24 VDC
1'666 mA
1'333 mA
833 mA
–12 VDC
–15 VDC
–24 VDC
1'666 mA
1'333 mA
833 mA
–12 VDC
–15 VDC
–24 VDC
1'666 mA
1'333 mA
833 mA
typ.
89 %
90 %
91 %
91 %
90 %
90 %
90 %
91 %
90 %
92 %
92 %
93 %
91 %
91 %
91 %
91 %
90 %
91 %
92 %
92 %
92 %
91 %
91 %
92 %
Page 1 / 5
TEN 40E Series, 40 Watt
Options
TEN-HS1
- Optional Heat Sink with Height = 0.22 inch: www.tracopower.com/products/ten-hs1.pdf
TEN-HS8
- Optional Heat Sink with Height = 0.3 inch: www.tracopower.com/products/ten-hs8.pdf
- Optional Heat Sink with Height = 0.8 inch: www.tracopower.com/products/ten-hs10.pdf
on demand
- Optional Heat Sink with Height = 0.5 inch: www.tracopower.com/products/ten-hs9.pdf
(backorder with MOQ
non stocking item) - Optional models with factory assembled heat-sink
- Optional models with inverse remote control
Input Specifications
Input Current
- At no load
12 Vin models:
24 Vin models:
48 Vin models:
12 Vin models:
24 Vin models:
48 Vin models:
12 Vin models:
24 Vin models:
48 Vin models:
12 Vin models:
24 Vin models:
48 Vin models:
Surge Voltage
Under Voltage Lockout
Recommended Input Fuse
Input Filter
20 mA typ.
15 mA typ.
10 mA typ.
25 VDC max. (1 s max.)
50 VDC max. (1 s max.)
100 VDC max. (1 s max.)
7 VDC min. / 8 VDC typ. / 8.8 VDC max.
15 VDC min. / 16 VDC typ. / 17.5 VDC max.
32 VDC min. / 33 VDC typ. / 35 VDC max.
8'000 mA (fast acting)
4'000 mA (slow blow)
2'000 mA (slow blow)
(The need of an external fuse has to be assessed
in the final application.)
Internal Pi-Type
Output Specifications
Output Voltage Adjustment
See application note:
Voltage Set Accuracy
Regulation
- Input Variation (Vmin - Vmax)
- Load Variation (0 - 100%)
Ripple and Noise
(20 MHz Bandwidth)
- Cross Regulation
(25% / 100% asym. load)
- single output
- dual output
single output models:
dual output models:
single output models:
dual output models:
dual output models:
3.3 Vout models:
5 Vout models:
12 Vout models:
15 Vout models:
24 Vout models:
12 / -12 Vout models:
15 / -15 Vout models:
24 / -24 Vout models:
–10% to +20% (15 & 24 Vout models)
±10% (other models)
(Single models only)
(By external trim resistor)
www.tracopower.com/overview/ten40e
Output power must not exceed rated power!
±1% max.
0.2% max.
0.2% max.
0.3% max.
0.5% max. (Output 1)
0.5% max. (Output 2)
5% max.
75 mVp-p typ.
75 mVp-p typ.
100 mVp-p typ.
100 mVp-p typ.
150 mVp-p typ.
100 / 100 mVp-p typ.
100 / 100 mVp-p typ.
150 / 150 mVp-p typ.
All specifications valid at nominal voltage, resistive full load and +25°C after warm-up time, unless otherwise stated.
www.tracopower.com
November 30, 2022
Page 2 / 5
TEN 40E Series, 40 Watt
Capacitive Load
- single output
3.3 Vout models:
5 Vout models:
12 Vout models:
15 Vout models:
24 Vout models:
12 / -12 Vout models:
15 / -15 Vout models:
24 / -24 Vout models:
- dual output
Minimum Load
Temperature Coefficient
Start-up Time
Short Circuit Protection
Output Current Limitation
Overvoltage Protection
Transient Response
- Response Time
22'000 µF max.
12'000 µF max.
2'000 µF max.
1'300 µF max.
490 µF max.
980 / 980 µF max.
630 / 630 µF max.
250 / 250 µF max.
Not required
±0.02 %/K max.
30 ms typ. / 60 ms max.
Continuous, Automatic recovery
150% typ. of Iout max.
125% typ. of Vout nom.
(By Zener diode)
250 µs typ. (25% Load Step)
Safety Specifications
Safety Standards
EN 62368-1
IEC 62368-1
UL 62368-1
www.tracopower.com/overview/ten40e
PD 2
- IT / Multimedia Equipment
- Certification Documents
Pollution Degree
EMC Specifications
EMI Emissions
- Conducted Emissions
- Radiated Emissions
EMS Immunity
External filter proposal:
Air:
Contact:
- Electrostatic Discharge
- RF Electromagnetic Field
- EFT (Burst) / Surge
Ext. input component:
- Conducted RF Disturbances
- PF Magnetic Field
Continuous:
1 s:
EN 55032 class A (with external filter)
EN 55032 class B (with external filter)
EN 55032 class A (with external filter)
EN 55032 class B (with external filter)
www.tracopower.com/overview/ten40e
EN 61000-4-2, ±8 kV, perf. criteria A
EN 61000-4-2, ±6 kV, perf. criteria A
EN 61000-4-3, 10 V/m, perf. criteria A
EN 61000-4-4, ±2 kV, perf. criteria A
EN 61000-4-5, ±2 kV, perf. criteria A
2 x KY 220 µF // SMDJ36A (12 Vin models)
2 x KY 220 µF // SMDJ58A (24 Vin models)
2 x KY 220 µF // SMDJ120A (48 Vin models)
EN 61000-4-6, 10 Vrms, perf. criteria A
EN 61000-4-8, 100 A/m, perf. criteria A
EN 61000-4-8, 1000 A/m, perf. criteria A
General Specifications
Relative Humidity
Temperature Ranges
Power Derating
Over Temperature
Protection Switch Off
Cooling System
- Operating Temperature
- Case Temperature
- Storage Temperature
- High Temperature
- Protection Mode
95% max. (non condensing)
–40°C to +85°C
+105°C max.
–55°C to +125°C
Depending on model
Depending on model (with Heat Sink)
See application note: www.tracopower.com/overview/ten40e
115°C typ. (Automatic recovery)
Natural convection (20 LFM)
All specifications valid at nominal voltage, resistive full load and +25°C after warm-up time, unless otherwise stated.
www.tracopower.com
November 30, 2022
Page 3 / 5
TEN 40E Series, 40 Watt
Remote Control
- Voltage Controlled Remote
- Off Idle Input Current
- Remote Pin Input Current
Switching Frequency
Insulation System
Isolation Test Voltage
Isolation Resistance
Isolation Capacitance
Reliability
Washing Process
- Input to Output, 60 s
- Input to Case, 60 s
- Output to Case, 60 s
- Input to Output, 500 VDC
- Input to Output, 100 kHz, 1 V
- Calculated MTBF
See Cleaning Guideline:
Environment
- Vibration
- Mechanical Shock
- Thermal Shock
Housing Material
Base Material
Potting Material
Pin Material
Pin Foundation Plating
Pin Surface Plating
Housing Type
Mounting Type
Connection Type
Footprint Type
Soldering Profile
Weight
Thermal Impedance
On: 3.0 to 12 VDC or open circuit
Off: 0 to 1.2 VDC or short circuit
Refers to 'Remote' and '-Vin' Pin
3 mA typ.
-0.5 to 1.0 mA
(Inverse Remote On/Off logic on demand)
225 - 275 kHz (PWM)
250 kHz typ. (PWM)
Functional Insulation
1'600 VDC
1'600 VDC
1'600 VDC
1'000 MΩ min.
1'500 pF max.
1'245'000 h (MIL-HDBK-217F, ground benign)
Allowed (hermetical product)
www.tracopower.com/info/cleaning.pdf
MIL-STD-810F
MIL-STD-810F
MIL-STD-810F
Copper
Non-conductive FR4 (UL 94 V-0 rated)
Silicone (UL 94 V-0 rated)
Copper
Nickel (2 - 3 µm)
Tin (3 - 5 µm), matte
Metal Case
PCB Mount
THD (Through-Hole Device)
2" x 1"
Wave Soldering
34 g
10.8 K/W typ. (without heatsink)
10.3 W/K typ. (with heatsink TEN-HS1)
9.3 W/K typ. (with heatsink TEN-HS8)
7.7 W/K typ. (with heatsink TEN-HS9)
6.2 W/K typ. (with heatsink TEN-HS10)
www.tracopower.com/info/reach-declaration.pdf
REACH SVHC list compliant
REACH Annex XVII compliant
www.tracopower.com/info/rohs-declaration.pdf
Exemptions: 7a, 7c-I
(RoHS exemptions refer to the component
concentration only, not to the overall
concentration in the product (O5A rule).
The SCIP number is provided on request.)
- Case to Ambient
Environmental Compliance - REACH Declaration
- RoHS Declaration
Supporting Documents
Overview Link (for additional Documents)
www.tracopower.com/overview/ten40e
All specifications valid at nominal voltage, resistive full load and +25°C after warm-up time, unless otherwise stated.
www.tracopower.com
November 30, 2022
Page 4 / 5
TEN 40E Series, 40 Watt
Outline Dimensions
(0.1)
Pinout
3
6
45.72 (1.8)
Dimensions in mm (inch)
Tolerances: x.x ±0.5 (±0.02)
x.xx ±0.25 (±0.01)
Pin dimension tolerance ±0.1 (±0.004)
25.4 (1.0)
5
(0.8)
Bottom View
(0.4)
2
20.32
4
1
10.16
Pin
Single
Dual
1
+Vin (Vcc)
+Vin (Vcc)
–Vin (GND)
–Vin (GND)
2
3
Remote On/Off Remote On/Off
4
+Vout
+Vout
5
–Vout
Common
6
Trim
–Vout
10.2
(0.4)
(0.22)
2.5 (0.1)
5.6
(0.3)
7.62
17.78 (0.7)
2.54
(2.0)
(0.1)
2.54
50.8
Ø1.0 (Ø0.04)
Rev. November 30, 2022
Page 5 / 5